Abstract

The effect of flow asymmetry was observed experimentally in vertical parallel channels of a continuous direct ohmic heater. While downward-oriented flow is evenly distributed at isothermal conditions, the flow rate in parallel channels differs in the case of heating due to buoyancy effects. Three different configurations of parallel flow (with and without internal heating in channels) are analyzed, giving critical values of Gr/Re or Ri = Gr/Re2 and ensuring stable and even distribution of flow into parallel channels of vertically oriented heat exchangers or heaters. Experimental verification was based upon flow visualization (injection of a colored tracer and monitoring the tracer by a camera), measurement of temperature profiles, and stimulus response experiments using KCl as a tracer for conductivity methods (2 Pt conductivity probes) and Tc99 as a radioisotope tracer (collimated scintillation detectors).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.