Pancreatic allograft thrombosis (PAT) remains the leading cause of nonimmunologic graft failure. Here, we propose a new computed tomography (CT) grading system of PAT to identify risk factors for allograft loss and outline a management algorithm by retrospective review of consecutive pancreatic transplantations between 2009 and 2014. Triple‐phase CT scans were graded independently by 2 radiologists as grade 0, no thrombosis; grade 1, peripheral thrombosis; grade 2, intermediate non‐occlusive thrombosis; and grade 3, central occlusive thrombosis. Twenty‐four (23.3%) of 103 recipients were diagnosed with PAT (including grade 1). Three (2.9%) grafts were lost due to portal vein thrombosis. On multivariate analysis, pancreas after simultaneous pancreas–kidney transplantation/solitary pancreatic transplantation, acute rejection, and CT findings of peripancreatic edema and/or inflammatory change were significant risk factors for PAT. Retrospective review of CT scans revealed more grade 1 and 2 thromboses than were initially reported. There was no significant difference in graft or patient survival, postoperative stay, or morbidity of recipients with grade 1 or 2 thrombosis who were or were not anticoagulated. Our data suggest that therapeutic anticoagulation is not necessary for grade 1 and 2 arterial and grade 1 venous thrombosis. The proposed grading system can assist clinicians in decision‐making and provide standardized reporting for future studies.