Abstract

The purpose of this study was to retrospectively compare the packing performance of helical Guglielmi detachable coil (GDC) 18 (thickness, 0.0135-0.015 inch) with the packing performance of both helical GDC 10 (thickness, 0.010 inch) and complex Trufill/Orbit coils (thickness, 0.012 inch). From our data base, we selected aneurysms that were exclusively coiled with GDC 18 coils. For every aneurysm treated with GDC 18 coils, we tried to identify a volume-matched control aneurysm treated with exclusively GDC 10 coils or exclusively Trufill/Orbit coils. This process resulted in 32 aneurysm pairs treated with either GDC 18 or GDC 10 coils and 35 aneurysm pairs treated with either GDC 18 or Trufill/Orbit coils. The mean packing of 24.2% of aneurysms treated with GDC 18 was significantly higher than the mean packing of 18.3% of aneurysms treated with GDC 10 (P<.0001). The mean packing of 23.1% of GDC 18 coils was not different from the mean packing of 25.1% of Trufill/Orbit coils (P=.15). In aneurysms of 4 mm or larger, packing performance of helical GDC 18 coils is superior to that of helical GDC 10 coils and equal to that of complex Trufill/Orbit coils.

Highlights

  • AND PURPOSE: The purpose of this study was to retrospectively compare the packing performance of helical Guglielmi detachable coil (GDC) 18 with the packing performance of both helical GDC 10 and complex Trufill/Orbit coils

  • We showed that packing is significantly higher in aneurysms treated with complexshaped coils of 0.012-inch wire thickness (Trufill/Orbit coils; Cordis Neurovascular, Miami Lakes, Fla) than with aneurysms treated with helical coils of 0.010-inch wire thickness (Guglielmi detachable coil [GDC] 10; Boston Scientific, Fremont, Calif).[4,5]

  • The increased packing of 0.012-inch coils over 0.010-inch coils was attributed to the increased coil thickness because the inserted coil length per aneurysm volume was equal

Read more

Summary

Objectives

The purpose of this study was to retrospectively compare the packing performance of helical Guglielmi detachable coil (GDC) 18 with the packing performance of both helical GDC 10 and complex Trufill/Orbit coils

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.