Abstract

This study reports the packaging effects of wafer-level chip scale packaging (WL-CSP) with a central opening on piezoresistive pressure sensors. A regular pressure sensor with calculated sensitivity of 3.1×10−2mVV−1kPa−1 and a sensitive pressure sensor with calculated sensitivity of 32.0×10−2mVV−1kPa−1 are investigated. A finite element (FE) model validated by experimental measurements is used to explore the sensing characteristics of the pressure sensors. The results show that the output variation of the packaged pressure sensor is dominated by the CTE mismatch not the piezoresistive coefficient change as temperature varies. WL-CSP with small polyimide (PI) thickness and large PI opening produces small packaging induced stress, making it ideal for precision sensing for both regular and sensitive pressure sensors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.