Abstract

We identified 33 patients with definite pacemaker endocarditis—that is, with direct evidence of infective endocarditis, based on surgery or autopsy histologic findings of or bacteriologic findings (Gram stain or culture) of valvular vegetation or electrode-tip wire vegetation. Most of the patients (75%) were ≥60 years of age (mean 66 ± 3; range 21 to 86). Pouch hematoma or inflammation was common (58%), but other predisposing factors for endocarditis were rare. At the time that pacemaker endocarditis was found, the mean number of leads was 2.4 ± 1.1 (range 1 to 7). The interval from the last procedure to diagnosis of endocarditis was 20 ± 4 months (range 1 to 72). Endocarditis appeared after pacemaker implantation, early (<3 months) in 10 patients and late (≥3 months) in 23 patients. Fever was the most common symptom, being isolated in 36%, associated with a poor general condition in 24%, and associated with septic shock in 9%. Transthoracic echocardiography showed vegetations in only 2 of 9 patients. Transesophageal echocardiography demonstrated the presence of lead vegetations (n = 20) or tricuspid vegetations (n = 3) in 23 of 24 patients (96%; p <0.0001 compared with transthoracic echocardiography). Pulmonary scintigraphy showed a typical pulmonary embolization in 7 of 17 patients (41%). Pathogens were mainly isolated from blood (82%) and lead (91%) cultures. The major pathogens causing pacemaker endocarditis were Staphylococcus epidermidis (n = 17) and S. aureus (n = 7). S. epidermidis was found more often in early than in late endocarditis (90% vs 50%; p = 0.05). All patients were treated with prolonged antibiotic regimens before and after electrode removal. Electrode removal was achieved by surgery (n = 29) or traction (n = 4). Associated procedures were performed in 9 patients. After the intensive care period, only 17 patients needed a new permanent pacemaker. Overall mortality was 24% after a mean follow-up period of 22 ± 4 months (range 1 to 88). Eight patients who were significantly older (74 ± 3 vs 63 ± 3 years; p = 0.05) died ≤2 months after electrode removal, whereas 25 were alive and asymptomatic.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.