Abstract
Abstract Background IQOS smoking (heat-no burn smoke product) is proposed to reduce harm compared to conventional smoking. We examined its effects on vascular function, myocardial deformation and ventricular arterial coupling. Methods Thirty-seven current smokers (mean age 48±5 years, >20 cigarettes /day) without cardiovascular disease and 20 healthy subjects with similar age sex and risk factors participated in the study. All subjects were instructed to smoke only IQOS for one month. Measurements were performed at baseline and 1 month after smoking IQOS. we measured a) the aortic PWV (PWV) and central aortic systole blood pressure (SBPc) by Complior; b) the exhaled CO level (parts per million-ppm) as a smoking status marker; and c) brachial systolic (SBP)and diastolic (DBP) blood pressure and heart rate (HR) a) flow mediated dilation (FMD) of the brachial artery b) coronary flow reserve (CFR) after adenosine infusion by Doppler echocardiography and c) global longitundinal strain (GLS) peak twisting and untwisting velocity and myocardial work index derived by pressure –myocardial strain loops by speckle tracking imaging PWV to GLS ratio was also used as a marker of ventricular arterial coupling Results At baseline exhaled CO, PWV, SBPc, FMD, PWV/GLS ratio, myocardial work index and peak untwisting velocity were higher and CFR was lower in smokers compared to controls (14.9±7 vs. 4.2±1 ppm, p<0.001, 8.7±1.4 vs 10.0±1.6 m/s, p<0.05; 118±16 vs 110±7 mmHg p<0.001, 6.9±2 vs 9.5±2% p<0.001, −0.61±0.21 vs. −0.45±0.11 m/sec%, p<0.001, 1926±284 vs 1826±300 mmHg% p=0.04, −122±36 vs −95±25 deg/sec, p=0.02, 2.5±0.9 vs. 3.1±0.8 p=0.001 respectively). In the chronic phase we observed a significant improvement of FMD, CFR, GLS, PWV/GLS, myocardial work index and peak untwisting velocity compared to baseline (12±2% vs. 6.9±2%, p=0.03; 3.2±0.6 vs. 2.5±0.9 p=0.001; −19.3±2.2% vs. −21.1±2.8%, p=0.001; −0.61±0.21 vs. −0.47±0.12 m/sec% p=0.03; 1926±284 vs 1830±343 mmHg% p=0.03, −122±36 vs −105±25 deg/sec, p=0.03, respectively) in parallel with reduction of the exhaled CO (14.9±7 vs. 6±4.9 ppm, p<0.001). HR remained unchanged throughout the study and there was a borderline reduction of central aortic systolic blood pressure (118±16 vs. 114±19 mmHg, p=0.048). Conclusions Replacement of conventional cigarettes with IQOS results in improved LV longitundinal myocardial deformation, LV untwisting and reduced LV myocardial work index possibly linked to the concomitant improvement of aortic elasticity, endothelial and coronary microcirculatory function and ventricular-arterial coupling within 1 month.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.