Abstract
AbstractIn this study, a new driving method is suggested to improve the luminance efficiency and the luminance. We applied a ramp pulse, instead of a square pulse, to an address period in Address Display period Separated, for operating on the Plasma Display Panels, which used the conventional gas [He‐Ne‐Xe]. When the ramp pulse is applied to the address period, improvement of the luminance and the luminance efficiency, and discharge response time was decreased. Additionally, infra red ray emission and discharge current were almost constant irrespective of the slopes of ramp pulse.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.