Abstract
Purpose In stereotactic body radiotherapy (SBRT), high-gradient dose is delivered and target volumes have to be delineated precisely in order to avoid irradiation of healthy tissue. Magnetic Resonance Imaging (MRI) acquisition in treatment position allows same spine curvature reproduction and shows to be useful to delineate organs at risk such as spinal cord. The aim of this study is to report the benefit of setting out an imaging protocol optimized for SBRT planning and to present a Volumetric Modulated Arc Therapy (VMAT) methodology to treat spine metastasis. Material and methods Patient immobilization and positioning was first set up at the GE Healthcare Planning CT scan with dedicated thermo-plastic nets, supports and cushions. An MR compatible table was designed by Orfit Industries and approved for testing by Siemens Healthcare. The same patient’s immobilization devices were used at the MR scan to perform optimized imaging series to reproduce treatment position. At the 1.5T Siemens Aera MR scan, head and body ex coils were used and imaging sequences were optimized to account for the table and immobilization devices. Coronal 3D Turbo Spin Echo T2-weighted and T1-weighted (3D TSE T2-w and 3D T1-w TSE) had the same acquisition matrix size and field-of-view with 1.00 mm slice thickness, resulting in isotropic voxel size of 1.00 mm3. TR/TE were 1100 ms/132 ms (T2-w) and 400 ms/18 ms (T1-w), respectively. Gross Target Volume (GTV) was contoured as the visible lesion on CT scan or hyper-signal on MR images. Clinical Target Volume was delineated upon GTV location according to [1]. The Planning Target Volume was defined as CTV + 2 mm. An optimized PTV was created: PTV2 = [PTV { (medullary canal + (spinal cord + 3 mm))]. VMAT dose plans were performed with AAA algorithm (Eclipse v11), 6MV fields and 1 mm calculation grid. The prescription was 3 * 9 Gy on the median volume of the PTV2. We compared different methods to decrease the dose outside the PTV2 (NTO function (Normal Tissue Objective) vs; NTO automatic vs. rings). A second study was performed to compare different configurations: 2 coplanar 360° arcs (collimators 15°/345° or 100°/80°) and 4 coplanar 360° arcs (collimators 15°/345/100°/80°). Results There was no problem of registration on the spine curvature between CT and MR images thanks to the table and immobilization devices (Fig. 1A). Examples of MR/Planning CT registration with benefit for target volume and organs at risk delineation are illustrated on Fig. 1B. Different geometries of PTV were considered, when spinous process was involved, 4 arcs are needed to better conform the PTV and respect the dose to the spinal cord. Dose plans reach good coverage of PTV2 (95% PTV received 96.8% of the prescribed dose), maximum dose for PTV2 was 105%. For the spinal cord +2 mm, max dose was 19.85 Gy, V11.1 Gy = 0.64 cc and V18Gy Conclusion Optimized imaging protocol in RT treatment position allows high precision registration with planning CT scan for a better delineation of target volume and organs at risk. All dose planning simulations fulfilled [1] , [2] , [3] the international recommendations. Download : Download high-res image (342KB) Download : Download full-size image
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.