Abstract

BackgroundThe MOMENTUM3 trial1 has revealed superiority of the novel HeartMate3 (HM3) left ventricular assist device (LVAD) compared with the HM2, with a significantly reduced occurrence of cerebrovascular accidents. Thus, cerebral autoregulation may be improved in HM3 compared with HM II patients, possibly because of altered microcirculatory haemodynamics associated with the in-built speed modulation (‘pulsatility’) of the HM3 device.MethodsAngle-corrected Doppler ultrasound images of the middle cerebral artery (MCA) were recorded before and at the end of a 30s breathhold test in healthy controls (n = 17), heart failure (HF n = 18), HM2 (n = 10) and HM3 (n = 17) patients. Microcirculatory haemodynamics as represented by the central retinal artery (CRA) were also quantified (Controls = 33, HF = 27, HM2 = 23, HM3 = 31). Data were analysed for Time-Averaged Maximum flow velocity (TAMAX), peak flow velocity (Vmax), minimum flow velocity (Vmin), Pulsatility Index (PI) and Resistance Index (RI, Table 1).ResultsBreathhold significantly increased TAMAX, Vmax and Vmin in all groups except HM II patients (Figure 1A). Conversely, PI decreased slightly in all groups while RI was maintained. The greater breathhold response in HM3 compared with HM2 patients was not attributable to the in-built pump-speed modulation (Figure 1B), however, HM3 had a consistently lower RI in the MCA and CRA.ConclusionAlthough reduced compared with healthy controls, HF and HM3 patients have a significantly greater metabolic cerebral vasoreactivity compared with HM2 patients. The 60% greater diastolic flow velocity in the microcirculation of both LVAD groups compared to healthy controls may alter gas exchange in the microcirculation. Future studies should examine the role of altered RI in HM3 patients.Table 1Haemodynamics in the middle cererbral artery (MCA) and the central retinal artery (CRA) between HeartMate2 and HeartMate3 patientsHealthy controls (n = 33)Heart failure (n = 27)HeartMate II (n = 23)HeartMate3 (average) (n = 31)HeartMate3 (no speed modulation) (n = 31)HeartMate3 (with speed modulation) (n = 31)Middle cerebral arteryTAMAX (cm/s)58 ± 1548 ± 1345 ± 1548 ± 1948 ± 1946 ± 18Vmax (cm/s)92 ± 2278 ± 2055 ± 19*#55 ± 21*#54 ± 21*#55 ± 22*#Vmin (cm/s)39 ± 1229 ± 1137 ± 1639 ± 1444 ± 16#32 ± 13Pulsatility index0.88 ± 0.181.05 ± 0.31*0.40 ± 0.24*#0.34 ± 0.14*#0.21 ± 0.12*#$0.56 ± 0.24*#Resistance index0.57 ± 0.070.60 ± 0.110.29 ± 0.14*#0.16 ± 0.09*#$0.17 ± 0.10*#$0.14 ± 0.09*#$Central retinal arteryTAMAX (cm/s)6 ± 15 ± 26 ± 37 ± 37 ± 46 ± 4Vmax (cm/s)12 ± 311 ± 68 ± 4*8 ± 4*8 ± 4*8 ± 4*Vmin (cm/s)3 ± 13 ± 15 ± 25 ± 36 ± 3*#4 ± 4Pulsatility index1.60 ± 0.451.42 ± 0.400.58 ± 0.26*#0.49 ± 0.21*#0.32 ± 0.17*#0.79 ± 0.35*#Resistance index0.75 ± 0.090.70 ± 0.110.38 ± 0.15*#0.22 ± 0.11*#$0.24 ± 0.12*#$0.20 ± 0.13*#$*p < 0.05 compared with healthy controls; #p < 0.05 compared with Heart Failure; $p < 0.05 compared with HeartMate II.Figure 1(A) Time-averaged maximum flow velocity in the middle cerebral artery of healthy controls and patient groups in response to a 30-s breathhold test. (B) Breakdown of the responses in HM3 patients, comparing beats with and without added pulsatility.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.