Abstract
Abstract Background The evolution of atrioventricular block (AVB) after Trans Aortic Valve Implantation (TAVI) is poorly understood, and indications of pacemaker (PM) implantation after TAVI not well defined. Modern PM algorithms can help studying the evolution of these AV conduction disorders after TAVI. SafeR® mode (Sorin® PM) allows to monitor precisely the AV conduction and to store AVB episodes in the PM memory as intracardiac electrograms, which can be re-read and validated afterwards. Methods From November 2015 and January 2017, all patients implanted in one of the 19 French enrolling centers with a Sorin® PM set in SafeR® mode after TAVI could be prospectively included in the study. All the PM interrogation files were centrally collected. The primary endpoint (PE) was the presence of at least one episode of high grade AVB (HG-AVB) beyond day 7 (D7) to one year after the TAVI. It could be validated either by the presence of a HG-AVB on EKG or telemetry, or by the confirmation of a HG-AVB in the PM memory files. Results 273 patients were included in the study, the PE was assessable in 197 patients. PE was validated in 74.6% patients. In univariate analysis, the use of an oversized prothesis or balloon, and all early episodes of HG-AVB (all those occurring up to D7) influence the validation of the PE. Other AV conduction disorders have no influence on the PE (Table). In multivariate analysis, only HG-AVB occurring between D2 and D7 has a significant influence on the PE. Factors influencing HG-AVB after TAVI Studied factor HG-AVB episode(s) during the one year follow up No HG-AVB episode during the one year follow up p value RBBB before TAVI (%) 41 34 0,346 Low implantation (>6mm) (%) 59 37 0,156 Use of Autoexpansive Valve (%) 62 62 0,990 Oversizing (%) 19 6 0,022 HG-AVB per TAVI (%) 56 30 0,001 HG-AVB D0-D1 (%) 53 24 0,001 HG-AVB D2-D7 (%) 68 34 0,001 New or wiser LBBB and improvement of PR interval after TAVI (%) 30 39 0,253 Influence of predefined factors on the Primary Endpoint. Conclusion The analysis of the SafeR® algorithm files in patients implanted with a PM after TAVI show a high incidence of HG-AVB during the one year follow up. In multivariate analysis, only HG-AVB occurring between D2 and D7 significantly influence the PE, confirming that AV conduction disorders occurring during the first 24 hours may spontaneously normalize. Acknowledgement/Funding Microport CRM
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.