A new reset method for high contrast ratio and reduction of the reset time is presented. In this new reset method, except the first subfield, a new reset pulse with only ramp-up period is adopted. In this reset method, from the third subfield, the background luminance generated during the reset period is theoretically zero until the first subfield of the following frame. Employing the new reset method, the dark room contrast ratio improved to 3084.7:1 from 189.1:1 of the conventional reset method. The new reset method reduced the required time for reset per subfield to 160us except the first subfield.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.