Abstract

Background: Interictal epileptiform discharges (IEDs) are known as epilepsy biomarkers for seizure detection, and It is essential for clinicians to detect them from from physiological events with similar temporal frequency characteristics. Methods: We analyzed the SEEG recordings obtained from patients with medically-resistant epilepsy (MRE) implanted with DE at the Western University Hospital Epilepsy Unit. The data were cleaned, denoised, montaged and segmented based on the clinical annotations, such as sleep intervals and observed Ictals. For event detection, the signal waveform and its power were extracted symmetrically in non-overlapping intervals of 500 ms. Each waveform’s power across all detected spikes was computed and clustered based on their energy distributions. Results: The recordings included thirteen sessions of 24 hours of extracellular recordings from two patients, with 312 hours extracted from four hippocampus electrodes anterior and posterior hippocampus. Our results indicate IEDs carrying the most different characteristics in the bands [25-75] Hz; SWR, on the other hand, are distributed between [80-170] Hz. Conclusions: Our algorithm detected and successfully distinguished IED from SWRs based on their carrying energy during non-sleep periods. Also, the most powerful spectral features that they were distinguished from occur in [15-30] Hz and [75-90] Hz.