Abstract

Background: Continuous video-EEG (cvEEG) monitoring is the standard of care for diagnosis and management of neonatal seizures. However, it is labour-intensive. We aimed to establish consistency in monitoring of newborns utilising NICU nurses. Methods: Neonatal nurses were trained to apply scalp electrodes, troubleshoot technical issues. Guidelines, checklists and visual training modules were developed. A central network system allowed remote access to the cvEEGs by the epileptologist for timely interpretation and feedback. We compared 100 infants with moderate to severe HIE before and after the training program. Results: 192 cvEEGs were performed. Of the 100 infants compared; time to initiate brain monitoring decreased by average of 31.5 hours, in electrographic seizure detection increased(20% compared to 34% a), seizure clinical misdiagnosis decreased (65% compared to 36% ), and Anti-Seizure burden decreased. Conclusions: Training experienced NICU nurses to set-up, start and monitor cvEEG can decrease the time to initiate cvEEG which may lead to better seizure diagnosis and management.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.