Abstract

This paper presents the degradation of imidacloprid by ozonation. Solutions of 39.0 μg/mL imidacloprid were prepared either by dissolution of standard or by dilution of Gaucho Blé ® seed loading solution and then ozonated under different conditions. The concentration of imidacloprid and oxidation products in both solutions was monitored by HPLC-UV as a function of the treatment time for a concentration of 100 g/m 3 of ozone in the inlet gas. No significant difference was observed: in both cases, imidacloprid degradation was a pseudo-first order reaction with similar reaction rates (0.129–0.147 min −1), degradation by-products with the same HPLC retention times were observed and their concentrations as a function of the treatment time followed a very similar trend. The study of ozone concentration in the inlet gas (from 25 to 100 g/m 3) showed that imidacloprid degradation is also a first-order reaction with respect to ozone. The ozonation by-products were then collected and identified by ESI(+)-MS. A degradation pathway of imidacloprid was finally proposed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.