Abstract
Abstract This study was directed at the investigation of technologies for treatment of water containing algal toxins at basic pH values. Ozonation, biofiltration and membrane filtration were examined for the removal of algal toxins, specifically microcystin-LR (MC-LR). Results indicate that, as expected, ozonation completely destroyed MC-LR in water, while biofiltration using naturally-occurring bacteria did not show a significant reduction in MC-LR concentration after eight days of contact time. More compelling were the membrane filtration results, which showed that water-affinity interactions were not the only governing factor influencing the removal of MC-LR by membranes. It was found that charge interactions between membranes and MC-LR played an important role in the rejection. MC-LR was completely removed from the feed water only by hydrophobic neutrally and positively charged membranes. Furthermore, due to charge interactions, MC-LR reversibly adsorbed to neutral hydrophobic membranes, but it irreversibly adsorbed to positive hydrophobic membranes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.