Abstract

AbstractA modified dynamic method is introduced to determine the oxygen transfer coefficient, KL a, in aerobic fermentation systems which are not mechanically agitated. The dissolved oxygen concentration is measured continuously following a step down or a step up in aeration rate. The response curve is analyzed to obtain the value of KLaExperiments were carried out at several different air flow rates using mixed culture in concurrent tower fermentors with motionless mixers. The effect of sieve trays and Koch motionless mixers on oxygen transfer was investigated using a 3 in. diameter column. The values of KL aobtained at the bottom of each column were found to be higher than those obtained at the top. Comparison of the results showed that the values ofKL a were higher when the Koch mixers were used than when the sieve trays were employed.The oxygen uptake rate by the organisms rX, is also calculated by using the KL a values obtained. They compare favorably withthe experimentally measured values.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.