Abstract

To measure and simulate oxygen kinetics during corneal cross-linking at different irradiances with and without supplementary oxygen. Experimental, laboratory study. In de-epithelialized porcine eyes, a femtosecond-laser-generated tunnel was used to place a fiber probe in corneal depths of 100, 200, and 300μm to measure the local oxygen concentration. After riboflavin imbibition, the corneas were irradiated at 3, 9, 18, and 30 mW/cm2 while the oxygen concentration was measured. All experiments were performed under normoxic (21%) and hyperoxic (>95%) conditions. The obtained data were used to identify parameters of a numerical model for oxygen consumption and diffusion. The equilibrium stromal oxygen concentration under atmospheric oxygen at 3 mW/cm2 was 2.3% in 100μm decreasing to <1% in 300μm. With 9, 18, and 30 mW/cm2, no oxygen was available in 200μm, respectively, 100μm or deeper. Using a hyperoxic environment, the concentration was 50% using 3 mW/cm2 in 100μm, decreasing to 40% in 300μm. At 9 mW/cm2, the concentrations were 5%, 3%, and 1% in 100, 200 and 300μm, respectively. Using 18 and 30 mW/cm2, all oxygen was depleted at 100μm; however, oxygen half-lives were longer at 18 mW/cm2 than at 30 mW/cm2. The oxygen model was able to reproduce the experiments and indicated an exponential decay with increasing distance to the anterior surface. Supplementary oxygen increases the oxygen availability during corneal cross-linking. At higher irradiances, supplementary oxygen is beneficial and eliminates the bottleneck of oxygen allowing a potentially more efficient cross-linking. The calibrated numerical model can quantify the spatial oxygen concentration related to different scenarios such as irradiance or environmental oxygen concentration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call