Abstract
AbstractThis paper provides an introduction to a comprehensive model being developed to predict and control oxide scale exfoliation from the steam‐side of superheater and reheater tubes in steam boilers. The model deals with the main phenomena involved in scale growth and failure in steam, and incorporates major variables related to boiler design and operation. The considerations used to calculate oxide growth under the specific constrains of small diameter tubes carrying high‐pressure steam and operating with large temperature gradients under temperature and pressure cycling conditions, as well as the evolution of stresses and strains in the scales, are indicated but only a cursory description is given of the details of the analytical treatments. An example is presented of calculations made with the model to predict the extent of blockage expected in a single superheater loop as a function of time and outlet steam temperature under several realistic service conditions. The results suggest that problems due to scale exfoliation would be expected early in the operating life of superheater tubes made from austenitic steel TP347H.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.