Abstract

Among particulate matter emissions from combustion processes, oil fly ash (OFA) displays a marked oxidative and inflammogenic reactivity, due to the high content of bioavailable transition metals. In the present study, we evaluated the biological effects of an OFA water solution, composed of the transition metals Fe (57.5%), V (32.4%), and Ni (10.1%), in human epithelial alveolar cells (A549 line). The fluorimetric analysis by 2',7'-dichlorofluorescein showed a significant, dose- and time-dependent induction of intracellular reactive oxygen species (ROS) triggered by OFA metal components at subtoxic doses. The metal chelator deferoxamine and the radical scavenger dimethylsulfoxide attenuated the metal-induced generation of ROS. Confocal microscopy observations strengthened these findings and showed an intense cytoplasmic fluorescence with perinuclear thickenings in A549 cells, in the absence of morphological damage. Metal-induced generation of ROS was significantly correlated with a dose- and time-dependent DNA damage, as assessed by single cell gel electrophoresis (comet assay). Catalase was able to decrease dramatically DNA damage. Fluorimetric analyses by diphenyl-1-pyrenylphosphine showed a parallelism between generation of ROS and formation of lipid peroxides. The results obtained in the experiments evaluating the effects of individual metal solutions did not show any significant difference in DNA damage between Fe(III) and V(IV), but highlighted the higher capability of V(IV) to increase ROS in the cytoplasmic compartment. The different behavior of these two elements, confirmed by the weak Fe-induced lipid peroxidation, may be ascribed to the presence of Fe-binding proteins, such as ferritin, in the cytoplasm. Finally, Ni(II) had negligible effects on ROS production. On the whole, the results obtained in this study show the strong capability of transition metals adsorbed to OFA to cause widespread damage to biological macromolecules, and suggest potential health effects resulting from exposure to power plant emissions in industrialized sites.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.