Abstract

The oxidation of Cr(III) at naturally-occurring concentration levels, i.e., µg dm(-3) or lower levels, by free chlorine during the chlorination process of tap water was studied using an improved solid-phase spectrophotometric method, which can be directly applicable to the specific determination of Cr(VI) at µg dm(-3) or lower levels. The effect of the pH on the oxidation kinetics was investigated under three different pH conditions. The results showed that free chlorine oxidized the Cr(III) to Cr(VI), following the pseudo-first-order kinetics with half lifetimes of 3.0, 3.3 and 14.4 h at pH 5.0, 7.0 and 8.0, respectively, if the hypochlorite concentration was maintained at 4 mg Cl dm(-3).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.