Abstract

Prosthetic vascular grafts placed surgically or via endovascular techniques can be subject to the risk of life-threatening graft infections. The Omniflow II vascular prosthesis is a biosynthetic graft that was reported to have favorable properties in resisting infections. We retrospectively reviewed our 3 years' experience of using the Omniflow II prostheses for aortoiliac reconstructions in patients considered to carry a substantial risk of subsequent prosthetic graft infections (prevention group) as well as in patients with actively infected prosthetic vascular grafts (treatment group). Aorto-bi-iliac (n = 4) and aortobifemoral (n = 12) vascular reconstructions were performed using bifurcated Omniflow II prostheses in nine patients in the prevention group and seven patients in the treatment group. During mean follow-up of 28.6 ± 17.2 months, there was one case of graft infection (6.3%) and graft thrombosis (6.3%) with subsequent successful thrombectomy. Early and late surgical revisions were required in eight (50%) and two (12.6%) patients, respectively. All graft prostheses were patent at last follow-up. Using bifurcated Omniflow II vascular prostheses in patients with or at a high risk of vascular graft infection is advisable, and is associated with acceptable reinfection and patency rates.