Abstract
Abstract Power handling experiments with a special liquid metal divertor module based on the capillary porous system technology were performed in the tokamak COMPASS. The performance of two metals (Li and LiSn alloy) were tested for the first time in a divertor under ELMy H-mode conditions. No damage of the capillary mesh and a good exhaust capability were observed for both metals in two separate experiments with up to 12 MW/m2 of deposited perpendicular, inter-ELM steady-state heat flux and with ELMs of relative energy ~3% and a local peak energy fluence at the module ~15 kJ.m−2. No droplets were directly ejected from the mesh top surface and for the LiSn experiment, no contamination of the core and SOL plasmas by Sn was observed. The elemental depth profile analysis of 14 stainless-steel samples located around the vacuum vessel for each experiment provides information about the migration of evaporated/redeposited liquid elements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.