Abstract

To assess the overall diagnostic accuracy of different MR imaging sequences in the detection of the dysplastic nodule (DN). PubMed, Cochrane Library, and Web of Science were systematically searched. Study selection and data extraction were conducted by two authors independently. Quality assessment of diagnostic accuracy studies (QUADAS) 2 in RevMan software was used to score the included studies and assess their methodological quality. A random-effects model was used for statistical pooling by Meta-Disc. Subgroup analysis and sensitivity analysis were used to explore potential sources of heterogeneity. Fourteen studies (335 DN lesions in total) were included in our meta-analysis. The area under the curve (AUC) of summary receiver operating characteristic (SROC) of T2WI was 0.87. Pooled sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of DWI were 0.81 (95%CI, 0.73-0.87), 0.90 (95%CI, 0.86-0.93), 7.04 (95%CI, 4.49-11.04), and 0.24 (95%CI, 0.17-0.33) respectively. In the arterial phase, pooled sensitivity, specificity, PLR, and NLR were 0.89 (0.84-0.93), 0.75 (0.72-0.79), 3.72 (2.51-5.51), and 0.17 (0.12-0.25), respectively. Pooled sensitivity, specificity, PLR, and NLR of the delayed phase were 0.78 (0.72-0.83), 0.60 (0.55-0.65), 2.19 (1.55-3.10), and 0.36 (0.23-0.55) separately. Pooled sensitivity, specificity, PLR, and NLR of the hepatobiliary phase were 0.77 (0.71-0.82), 0.92 (0.89-0.94), 8.74 (5.91-12.92), and 0.24 (0.14-0.41) respectively. Pooled sensitivity, specificity, and PLR were higher on DWI and hepatobiliary phase in diagnosing LGDN than HGDN. MR sequences, particularly DWI, arterial phase, and hepatobiliary phase imaging demonstrate high diagnostic accuracy for DN. • MRI has dramatically improved the detection and accurate diagnosis of DNs and their differentiation from hepatocellular carcinoma. • Overall diagnostic accuracy of different MRI sequences in the detection of DN has not been studied before. • Our meta-analysis demonstrates that MRI achieves a high diagnostic value for DN, especially when using DWI, arterial phase imaging, and hepatobiliary phase imaging.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.