Abstract

Nitrogen and water accumulations in fuel cells with dead-ended anode can cause severe cell performance decline and fluctuations. In this work, both overall and local effects of fuel cell operating parameters, i.e., cathode humidity, air stoichiometry, hydrogen pressure and operating current density, have been experimentally studied under galvanostatic mode. A purge at the anode is automatically triggered when the cell voltage has decreased by 0.1 V and the mean purge interval, defined as the average time between two purges, is recorded as a characteristic parameter. Local current densities are measured to study the local effects and detailed local characteristics of the fuel cell. The experimental results show that mean purge intervals decrease with cathode inlet humidity and operating current density, and increase with inlet hydrogen pressure and air stoichiometry. The experimental results also show that the local current densities change very differently at different locations and impurities first accumulate near the end of the anode channel and then gradually progress upstream.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.