Abstract

Although endoscopic ultrasound (EUS) is generally safe, duodenal perforation may occur during the procedure. When the iatrogenic break is wide, endoscopic positioning of a covered self- expandable metal stent is indicated to avoid a more invasive surgical approach. We evaluated the efficacy of the 'over-the-scope stenting' (OTSS) technique to treat iatrogenic duodenal perforations occurred during EUS. Data of patients with large iatrogenic duodenal perforations treated with OTSS procedure were collected in 5 centers. Technical success was defined as a correct stent placement on the perforation site, and clinical success as complete healing of the duodenal leak at stent removal 3 weeks later. A total of 15 (7 males; median age: 78 years, range 47-91) patients were included in this series. A correct stent positioning was achieved in all cases (technical success: 100%), and the perforation was healed in all, apart from one patient at stent removal (clinical success: 93%). This patient was successfully treated with a novel stent placement. No immediate post-procedural adverse events occurred, and no need for emergency surgery was recorded. In one (6.7%) patient, stent migration occurred 10 days after positioning, and it was spontaneously expulsed with stool movement without complications two days later. Our data showed that the OTTS technique for partially covered self-expandable metal stent placement is feasible, safe and effective to tread large iatrogenic duodenal perforation occuring during EUS.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call