Abstract

In this paper, we propose two control methods of the static impulse voltage generator to lower the influence of DC voltage source fluctuations on the output voltage and to improve its efficiency by reusing discarded inductive storage energy. Introducing the output voltage control adjusting the charging period of capacitive and inductive energy in accordance with the source voltage, the output voltage fluctuation by the source voltage decreased 61.1%. Applying the reusing method to it, we estimated with the circuit simulation that the amount of energy which could be recovered was 21.0% and the efficiency of energy transfer was improved from 60.4% to 76.7%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call