Abstract
Methods and procedures for outdoor sound power measurement for reference sound sources according to ISO 6926/ANSI 12.5 are discussed. This method assures no low‐frequency cutoff of the sound power determination. A quiet outdoor site with a sealed surface of suitable radius, clear of structures and trees is required. Measurement plan‐positions are marked on the surface. Equipment components are prepared in advance for efficient deployment. Weather forecasts are used to determine day or night measurement periods that are free of rain and wind. When ready, site barometric pressure, dry bulb temperature, and wet bulb temperature are measured. The microphone height and the 2 m radius are positioned with a fixture. Sound pressure level data are acquired at all microphone positions, serially if necessary. Sound power results are corrected to standard conditions. High‐frequency results are corrected for humidity as it affects sound absorption by air. Results obtained over several years and at a variety of temperatures are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.