Abstract

We present the outline of a model that calculates the outdoor performance of a bifacial module including optical, electrical and thermal aspects. The IV curve for the total module power output is obtained by scaling or weighting the 2-diode parameters of front and rear standard test conditions (STC) module IV curves with the calculated front and rear irradiance. Validation and verification of the electrical model are given through simulations and measurements. Annual yield gain predictions based on measured characteristics of bifacial modules are presented and discussed for vertical,east-west bifacial modules relative to south-facing tilted monofacial modules. For a module with a bifaciality factor of 92% in a location like Amsterdam, this predicted annual yield gain is in the order of 10% at albedo 0.2 and 30% at albedo 0.5.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.