Abstract

ABSTRACT For people with disabilities or chronic diseases, an electrically supported tricycle (e-trike) could facilitate independence and participation in physical activity, and improve health conditions. This study investigates the exercise intensity and perceived exertion of e-trike cycling. Twenty healthy participants cycled on an e-trike with different speeds (12 and 18 km/h) and different levels of electric pedal support at an outdoor athletics track. Exercise intensity was measured with oxygen consumption () using a Cosmed K4B2 analysis unit, perceived exertion was measured with the Borg Rating of Perceived Exertion scale, pedaling power, and engine power were measured with a torque sensor. The effect of speed and support was analyzed with a Linear Mixed Effects model. was 18.67 ± 3.13 ml/kg/min without support, with electric support the exercise intensity was significantly below moderate intensity (i.e. 10.5 ml/kg/min) at t = 11.37, p < .001, 95% CI: 1.90, 2.77. The Borg score without support was 9.79 ± 1.72 and all other conditions below this, which were significantly below moderate intensity (i.e. 11) at t = −3.07, p = .007, 95% CI: −2.04, −0.38. Speed and support significantly affected (F = 185.49, p < .001). E-trike cycling is a low intensity activity, but intensity can be influenced by changing speed and support level.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call