Abstract

To report the functional outcomes of robot-assisted laparoscopic artificial urinary sphincter implantation (R-AUS) in men with neurogenic stress urinary incontinence (SUI). A monocentric retrospective study included all consecutive adult male neuro-urological patients who underwent R-AUS for SUI between January 2011 and August 2018. The AUS was implanted via a transperitoneal robot-assisted laparoscopic approach. Intraoperative and early postoperative complications were reported (Clavien-Dindo classification). Continence was defined as no pad usage. Revision and explantation rates were also evaluated. Overall, 19 men with a median (interquartile range [IQR]) age of 45 (37-54) years were included. No conversion to laparotomy was needed. Three minor (Clavien-Dindo Grade I-II) early postoperative complications occurring in three (15.8%) patients were reported. The median (IQR) follow-up was 58 (36-70) months. At the end of the follow-up, the continence rate was 89.5%. The AUS revision and explantation rates were 5.3% and 0%, respectively. A R-AUS is a safe and efficient procedure for AUS implantation in adult male neuro-urological patients, referring to the challenging open technique.