Abstract

To review outcomes of male patients attending the breast unit, evaluate effectiveness of imaging and examination in detecting breast cancer and review adherence to guidelines for male breast imaging. A retrospective review was undertaken of male patients attending Cambridge Breast Unit from 1 January 2015 to 31 December 2019. Patient electronic records and imaging were reviewed to establish demographics, clinical findings, imaging, biopsy, and pathology outcomes. Of 1,362 male patients attending the breast unit, 1,028 (75%) had imaging performed. Biopsy was performed in 41 men (3%), with 14 cancers diagnosed (1%). Clinical examination showed 42.7% sensitivity, 99.6% specificity, 54.6% positive predictive value (PPV) and 99.4% negative predictive value (NPV) for detection of cancer. Mammogram demonstrated 84.6% sensitivity, 99.4% specificity, 69.8% PPV, and 99.8% NPV for detection of malignancy. Ultrasound demonstrated 78.6% sensitivity, 98.9% specificity, 73.3% PPV and 99.2% NPV for detection of cancer. Forty-one percent of patients <40 years and 51%<50 years were imaged, who according to local and Royal College of Radiologists (RCR) guidelines did not require imaging based on age and clinical score. Male patients account for a small proportion of referrals to the breast unit but generate significant workload. Imaging protocols, incorporating clinical score and age cut-off at 40 years remains robust for detecting malignancy. Clinician awareness of the imaging protocol, and close liaison with radiologists is essential to minimise additional radiology workload.