Abstract

We compared the outcomes of fenestrated-branched (FB) endovascular abdominal aortic aneurysm repair (EVAR) using low-profile (LP) and standard-profile (SP) stent grafts for the treatment of complex abdominal aortic aneurysms (CAAAs) and thoracoabdominal aortic aneurysms (TAAAs). We reviewed the clinical data of 466 consecutive patients (70% male; mean age, 74± 8years) enrolled in a prospective nonrandomized study to investigate FB-EVAR for the treatment of CAAAs and TAAAs (2013-2021). The endpoints compared between the patients treated with LP (18F-20F) and SP (20F-22F) devices included procedural metrics, access-related complications, major adverse events (MAE), patient survival, freedom from secondary intervention, thromboembolic events, stent graft integrity issues, aneurysm sac enlargement, and the rate of sac shrinkage. Of the 466 aneurysms treated by FB-EVAR, 138 were CAAAs and 141 were extent IV and 187 extent I to III TAAAs, with a mean number of 3.9± 0.5 vessels stented per patient. LP devices had been used in 239 patients (51%) and SP devices in 227 patients (49%). LP devices had been used more frequently for chronic dissections (12% vs 7%; P= .041) and with preloaded systems (77% vs 65%; P= .005) and bilateral percutaneous femoral access (83% vs 74%; P= .020) and less frequently with upper extremity access (67% vs 88%; P< .001) and iliac conduits (2% vs 6%; P= .020). The patients treated using LP devices had experienced similar technical success (96% vs 97%; P= .527), with a shorter total operating time (225± 81minutes vs 243± 78minutes; P= .018), lower radiation exposure (median, 0.93Gy; interquartile range [IQR], 0.94; vs median, 1.01Gy; IQR, 0.91Gy; P< .001), and less use of contrast (median, 135mL; IQR, 68mL; vs median, 144mL; IQR, 80mL; P= .008). No differences were found in the rates of iliofemoral access complications between the LP and SP device groups (1.3% vs 3.5%; P= .107). At 30days, 5 patients had died (1%) and MAEs had occurred in 89 patients (19%), with no differences between the two groups. The mean follow-up was 28months (95% confidence interval, 25-30months). At 4years, the patients treated with LP devices had had similar freedom from all-cause mortality (69%± 6% vs 68%± 4%; P= .199), freedom from aortic-related mortality (97%± 1% vs 98%± 1%; P= .488), freedom from any secondary intervention (65%± 6% vs 70%± 4%; P= .433), freedom from thromboembolic events (98%± 1% vs 99%± 1%; P= .364) and aneurysm sac enlargement (93%± 3% vs 91%± 3%; P= .293). However, the LP group had had less freedom from any integrity-related issues (92%± 5% vs 100%; P< .001). The cumulative risk of sac shrinkage was greater for patients treated with LP devices (adjusted hazard ratio, 2.040; 95% confidence interval, 1.516-2.744; P< .001). FB-EVAR was performed with low rates of mortality and MAEs, irrespective of the device profile. However, the procedures performed with LP devices had had less need for iliac conduits and had had better procedural metrics. The use of LP devices resulted in higher rates of sac shrinkage. However, the results on stent graft integrity require future investigation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call