Abstract
Introduction Reversepolarity shoulder arthroplasty (RSA) is an evolving surgery, and its indications have expanded over time. Apart from cuff tear arthropathy (CTA), it is recommended for complex proximal humerus fractures in the elderly, inflammatory arthritis, primary osteoarthritis in the elderly, and revision for failed hemiarthroplasty. Glenoid base plate placement and fixation are important to prevent complications, especially glenoid base plate loosening, dislocation, and scapular notching, and to improve longevity. Guided personalized surgery (GPS)-navigated RSA was devised to optimize the glenoid base plate position and fixation. Methodology A retrospective study was carried out in a low-volume district general hospital in England. All the patients who underwent GPS-navigated RSA were included. Their preoperative glenoid version, bone stock, glenoid base plate, and glenoid screw lengths were analysed. Preoperative and post-surgery patient-reported outcomes were gathered using the Oxford Shoulder Score (OSS) at six months and annually thereafter. Results Fourteen patients have undergone GPS-navigated RSA in our institute since 2018. Ten patients were female. All of them had a retroverted glenoid with a mean value of 13.6 degrees. Ten out of 14 patients had an augmented glenoid base plate. This included six eight-degree posterior augmentations, three 10-degree superior augmentations, and one extended cage peg. The follow-up period was six months to five years, depending on the date of surgery, and none of the patients dropped out of follow-up. The OSS revealed statistically significant improvement from preoperative values to six months postoperative, an improvement of 21.64±7.175. It also showed progressive improvement over time during postoperative follow-up, and the three-year mean was 47. The commonest complication was fractures, which happened in four cases. There were no infections or dislocations. Discussion Guided personalized surgery-navigated RSA was performed on selected patients at our institution when they were not suitable for conventional RSA due to distorted glenoid anatomy. Glenoid base plate positioning and fixation are important to optimize the outcome of RSA. Guided personalized surgery navigation is helpful in achieving optimum glenoid base placement, especially when the normal glenoid anatomy is distorted. There were no dislocations, glenoid base plate loosening, or scapular notching in the study group. There were four reported fractures, which was comparable with the published literature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.