Abstract

Background: New generation of total trapeziometacarpal joint prosthesis using double mobility concept has been used for several years. The aim of this study was to evaluate the dislocation rate with this implant after a minimal 3 years of follow-up. Methods: From September 2013 to August 2015, 200 trapeziometacarpal prostheses were implanted in 179 patients. Clinico-radiological follow-up was performed with an average of 48.2 months (36-60 months). Survival rate and dislocation rate were analyzed. Loosening of the implants and other intercurrent events were noticed. Results: Visual analog scale, Quick-DASH, strengths and range of motion improved significantly. We report a survival rate of 97% with only 0.5% of dislocation of prosthesis at 48 months of follow-up. Intercurrent events rate were similar to the ones found in literature or other studies. Conclusions: After a minimal of 3 years of follow-up, prosthesis with double mobility seemed to bring better stability in implant for thumb prosthetic replacement.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call