Abstract

BackgroundOutcomes have improved in patients bridged to heart transplant on contemporary continuous-flow ventricular assist devices over the past decade. We evaluated mechanical circulatory support as a means to bridge patients to cardiac retransplantation. MethodsWe retrospectively reviewed 464 patients who underwent cardiac retransplant from the United Network for Organ Sharing database between January 2006 and November 2016. Pre- and post-transplant data were compared between patients bridged to retransplant with mechanical circulatory support (n = 81) and those without mechanical circulatory support (n = 383). ResultsThe mean ages for the patients in the mechanical circulatory support and nonmechanical circulatory support cohorts were 41.2 ± 16 years and 42.1 ± 15.7 years, respectively (P = .64). Patients bridged with mechanical circulatory support were placed on extracorporeal membrane oxygenation (n = 29, 35.8%), a total artificial heart (n = 13, 16.0%), or a temporary or durable ventricular assist device (n = 39, 48.1%). Twelve patients (14.8%) were placed on a second device before retransplant. Thirty-nine percent of the mechanical circulatory support group were indicated for listing because of primary graft dysfunction or acute rejection versus 6% of the nonmechanical circulatory support group (P < .01). Likewise, 30% of patients in the mechanical circulatory support group were listed for cardiac allograft vasculopathy compared with 59% of the nonmechanical circulatory support group (P < .01). Thirty-day mortality was significantly higher in the mechanical circulatory support group (17.8% vs 4.8%, P < .01). However, patients who were bridged with a ventricular assist device or total artificial heart had comparable midterm outcomes to the nonmechanical circulatory support group. ConclusionsPatients who require mechanical circulatory support bridge to retransplantation belong to a high-risk cohort. Comparable midterm outcomes to the nonmechanical circulatory support cohort were demonstrated when patients' conditions allow for bridge with a ventricular assist device or total artificial heart. Bridging to retransplantation with extracorporeal membrane oxygenation remains a relative contraindication.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.