Abstract

Resorbable biomaterials have been developed to reduce the amount of foreign material remaining in the body after hernia repair over the long-term. However, on the short-term, these resorbable materials should render acceptable results with regard to complications, infections, and reoperations to be considered for repair. Additionally, the rate of resorption should not be any faster than collagen deposition and maturation; leading to early hernia recurrence. Therefore, the objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (Phasix™) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair. A prospective, multi-center, single-arm trial was conducted at surgical departments in 15 hospitals across Europe. Patients aged ≥18, scheduled to undergo elective Ventral Hernia Working Group Grade 3 hernia repair of a hernia larger than 10cm2 were included. Hernia repair was performed with Phasix™ Mesh in sublay position when achievable. The primary outcome was the rate of surgical site occurrence (SSO), including infections, that required intervention until 3 months after repair. In total, 84 patients were treated with Phasix™ Mesh. Twenty-two patients (26.2%) developed 32 surgical site occurrences. These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula. No significant differences in surgical site occurrence development were found between groups repaired with or without component separation technique, and between clean-contaminated or contaminated wound sites. At three months, there were no hernia recurrences. Phasix™ Mesh demonstrated acceptable postoperative surgical site occurrence rates in patients with a Ventral Hernia Working Group Grade 3 hernia. Longer follow-up is needed to evaluate the recurrence rate and the effects on quality of life. This study is ongoing through 24 months of follow-up.

Highlights

  • IntroductionWith a re­ ported infection rate of about 5%, synthetic meshes are more prone to infection than biological tissue-derived materials [10]

  • This study is ongoing through 24 months of follow-up

  • Twenty-five patients (29.8%) had other significant medical history not listed in Table 3, such as an intersphincteric fistula, Crohn’s disease, pancreatitis, depression, hip replacement, cholecystectomy, or posttraumatic stress syndrome, among others

Read more

Summary

Introduction

With a re­ ported infection rate of about 5%, synthetic meshes are more prone to infection than biological tissue-derived materials [10]. This could pose a problem in potentially contaminated hernias like Ventral Hernia Working Group (VHWG) Grade 3 hernias (Table 1) [11]. The objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (PhasixTM) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair. Twenty-two patients (26.2%) developed 32 sur­ gical site occurrences These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula.

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call