Abstract

Introduction: Cardiac surgery is associated with significant morbidity and longer length-of-stay (LOS) than most other surgeries. Regional cerebral oximetry (rSO2) using near-infrared spectroscopy (NIRS) on the patient’s forehead monitors cerebral oxygenation during surgery and cardiopulmonary bypass (CPB). Its purpose is to detect and manage periods of cerebral hypoxia which may otherwise go undetected, thereby reducing morbidity. But outcomes have been inconsistent, and not all cardiac departments have adopted this non-invasive, simple-to-use technology. We aimed to study the efficacy of our use of rSO2 by recording seven outcomes for each patient according to their preoperative rSO2, the mean intraoperative rSO2, and four ischemic thresholds during surgery.Method: This is a retrospective audit of cardiac surgical patients in whom a protocol was used to maintain rSO2 above the preoperative value and studied seven major morbidity outcomes. Cerebral oximetry data were recorded for each patient and analyzed for six variables: preoperative baseline rSO2, mean intraoperative rSO2, and four ischemic thresholds defined as an area under the curve (AUC) in minutes% below the baseline rSO2,minus 10% below the baseline, minus 20% the below baselineand minus 50% below baseline. Outcomes examined were: delirium, stroke, postoperative rise in creatinine of 50 mmol, absolute creatinine of 200 mmol, need for new renal replacement therapy (RRT), hospital LOS and inpatient mortality.Results: Complete data were available for 166 patients. Lower mean preoperative rSO2 was associated with stroke (p=0.031), mild and severe renal dysfunction (p=0.045 and p=0.036), death-in-hospital (p=0.027) and prolonged hospital LOS (p=0.005). Lower mean intraoperative rSO2 during surgery was associated with the outcomes of renal dysfunction, mild (p=0.027), moderate (p=0.003) or severe (p=0.002), death-in-hospital (p=0.003) and prolonged hospital LOS (p=0.015). Of the four ischemic thresholds defined, only new RRT occurring at minus 20% and minus 50% below baseline was significant.Conclusion: Lower preoperative rSO2 and mean intraoperative rSO2 were associated with poor outcomes, notably leading to a significant increase in hospital LOS. Mild degrees of cerebral ischemia below the baseline and minus 10% of the baseline during surgery were well tolerated.

Highlights

  • Cardiac surgery is associated with significant morbidity and longer length-of-stay (LOS) than most other surgeries

  • We aimed to study the efficacy of our use of rSO2 by recording seven outcomes for each patient according to their preoperative rSO2, the mean intraoperative rSO2, and four ischemic thresholds during surgery

  • Cerebral oximetry data were recorded for each patient and analyzed for six variables: preoperative baseline rSO2, mean intraoperative rSO2, and four ischemic thresholds defined as an area under the curve (AUC) in minutes% below the baseline rSO2, minus 10% below the baseline, minus 20% the below baseline and minus 50% below baseline

Read more

Summary

Introduction

Cardiac surgery is associated with significant morbidity and longer length-of-stay (LOS) than most other surgeries. Regional cerebral oximetry (rSO2) using near-infrared spectroscopy (NIRS) on the patient’s forehead monitors cerebral oxygenation during surgery and cardiopulmonary bypass (CPB). Cerebral oximetry is a real-time technique to non-invasively measure cerebral oxygenation using near-infrared spectroscopy (NIRS). The reflected signal gives a measure of the regional cerebral oximetry (rSO2) of the hemoglobin in that area of the brain. The initial focus for improvement was on two principal areas - neurological injury and major organ morbidity for which the brain would act as an index organ [3].

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.