Abstract

To assess the outcome of implant diameter and length on THE distribution of stress using a three-dimensional (3D) finite elements (FE) analysis, with immediate loading implants. This study made use of a 3D FE model of an implant encased in a chunk of bone. The LEADER/ITALIA-Fix type implant was created specifically for immediate loading. To create a solid model of the implant and bone and to carry out the FE analysis, the ANSYS V.12 programme was used. The findings indicated that the neck of dental implants is the area of highest stress for all implant diameters and lengths, with an increase in implant length from 10 mm to 12 mm resulting in a slight raise in stress at the interface of implant-bone, and an increase in diameter from 3.75 mm to 4.25 mm having no appreciable impact on the value of stresses around dental implants. It was concluded that an increase in length has a negative effect on stress, while a diameter increase has no discernible impact on stress values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.