Abstract

This paper investigates the out-of-plane shear behavior of composite steel-plate-reinforced concrete walls (SC walls) and proposes their shear-strength-models based on plasticity theory limit analysis. For speedy, modular construction, SC walls are fabricated using double-skin steel plates with welded shear studs and sandwiching concrete between them. A review of current design formulas provides better understanding of bond-stress-dependent shear behavior relying on studs of SC walls. We conducted experiments on bondstrength-dependent arch and/or truss action to verify proposed shear-strength models with test results. Test results, including those from literature, agreed well with the strength anticipated by proposed formulas.