Abstract

Nowadays there is still a lack of requirements for the out-of-plane design of confined masonry walls. Current code requirements are mainly based on the in-plane behavior of those walls. This research is divided into two parts. In the first part, two confined walls subjected to out-of-plane uniform loads were tested in the laboratory. Confining elements with minimum cross-section dimensions and wall aspect ratios smaller than one were considered. The variable studied was the wall length. Out-of-plane load—displacement curves of walls were obtained. In the second part, two design equations were developed to determine the out-of-plane strength of confined walls. A design equation was developed to determine the corresponding in-plane forces transferred to the confining elements. The out-of-plane strength of 6912 walls was determined using a computer program based on the bidirectional strut method. A parametric analysis was carried out for the out-of-plane strength considering different variables. Multiple linear regression analyses were carried out to propose out-of-plane strength design equations. It was concluded that the experimental out-of-plane strength increased, and the wall failure type changed as the wall length decreased. In addition, the experimental out-of-plane strength of walls was well predicted with both out-of-plane design equations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.