An out-of-plane linear coefficient of thermal expansion (CTE) measurement method was developed to overcome the difficulty in measuring the in-plane deformation of freestanding thin films with a thickness of less than 1 μm. The out-of-plane profile measurement was relatively easy with the added advantage of simplicity, easy specimen preparation, and a simple test setup. White light interferometry was used for determining the out-of-plane thermal deformation as a function of temperature. Two types of supporting substrates, silicon and ZERODUR®, were used to account for the substrate effect on the CTE measurement. Attempts were made to fit the measured profiles using several peak functions and then find the optimal one. The test procedures were demonstrated using a freestanding 530-nm-thick aluminum film that was used in a previous in-plane measurement method. The calculated CTE value of this aluminum film was 23.7 ppm/°C, which was in good agreement with the in-plane measurement result. The out-of-plane CTE measurement method incorporating a zero CTE substrate was shown to be the most convenient and straightforward method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.