Abstract

To measure the out-of-field mean photon energy and dose imparted by the secondary radiation field generated by 6 MV and 6 MV FFF beams using TLD-300 and TLD-100 dosimeters and to use the technique to quantify the contributions from the different sources that generate out-of-field radiation. The mean photon energy and the dose were measured using the TLD-300 glow curve properties and the TLD-100 response, respectively. The TLD-300 glow curve shape was energy-calibrated with gamma rays from 99m Tc, 18 F, 137 Cs, and 60 Co sources, and its energy dependence was quantified by a parameter obtained from the curve deconvolution. The TLD-100 signal was calibrated in absorbed dose-to-water inside the primary field. Dosimeters were placed on the linac head, and on the surface and at 4.5cm depth in PMMA at 1-15cm lateral distances from a 10 × 10 cm2 field edge at the isocenter plane. Three configurations of dosimeters around the linac were defined to identify and quantify the contributions from the different sources of out-of-field radiation. Typical energies of head leakage were about 500keV for both beams. The mean energy of collimator-scattered radiation was equal to or larger than 1250keV and, for phantom-scattered radiation, mean photon energies were 400keV for the 6 MV and 300keV for the 6 MV FFF beam. Relative uncertainties to determine mean photon energy were better than 15% for energies below 700keV, and 40% above 1000keV. The technique lost its sensitivity to the incident photon energy above 1250keV. On the phantom surface and at 1-15cm from the field edge, 80%-90% of out-of-field dose came from scattering in the secondary collimator. At 4.5cm deep in the phantom and 1-5cm from the field edge, 50%-60% of the out-of-field dose originated in the phantom. At the points of measurement, the head leakage imparted less than 0.1% of the dose at the isocenter. The 6 MV FFF beam imparted 8-36% less out-of-field dose than the 6 MV beam. These energy results are consistent with general Monte Carlo simulation predictions and show excellent agreement with simulations for a similar linac. The measured out-of-field doses showed good agreement with independent evaluations. The out-of-field mean photon energy and dose imparted by the secondary radiation field were quantified by the applied TLD-300/TLD-100 method. The main sources of out-of-field dose were identified and quantified using three configurations of dosimeters around the linac. This technique could be of value to validate Monte Carlo simulations where the linac head design, configuration, or material composition are unavailable.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call