Abstract
This study aimed to share our experience with infants with repaired long-gap esophageal atresia (LGEA) using the native esophagus and Foker and Gazi methods. We retrospectively analyzed the medical records of 10 patients with LGEA (six with pure esophageal atresia [EA], and four with distal trachea-esophageal fistula [TEF] + EA). The mean length between the esophageal pouches was 5.9 cm (4-9 cm). Five Foker methods, three Gazi methods, and two delayed primary repairs after a daily bougie were performed an average of 19.3 days after the first surgery and 26.4 days after the final esophageal anastomosis. For the Foker technique, it was 36.1 days. Their first oral intake was 10.2 days, and their transition to full enteral food was 26.2 days. An esophageal leak was detected in six patients. Fundoplication and dilatations were performed for three and four patients, respectively. For good results, LGEA patients should be operated on at least under the supervision of an experienced surgeon in specialized centers, and the team should be familiar with the techniques for using the native esophagus.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.