Abstract

Recent advances in endoscopic technology have allowed its application to middle ear surgery. An antifog agent is necessary for endoscopy because moisture and blood may obscure visibility. Ultrastop is one of the most commonly used antifog agents. The current study examined the ototoxic effect of topical application of Ultrastop in the guinea pig ear. A preliminary experimental animal study. University hospital. Eighteen male Hartley guinea pigs (weight, 480-620 g) were divided into 3 groups to be treated with Ultrastop, gentamicin (50 mg/mL, positive control), or saline solution (negative control). After auditory brainstem responses were measured, topical solutions of 0.2 mL were applied through a small hole made at the tympanic bulla. Posttreatment auditory brainstem responses were obtained 14 days after the treatment. The extent of middle ear damage was investigated and scored. The saline-treated group showed no deterioration in auditory brainstem response threshold. The Ultrastop-treated and gentamicin-treated groups showed severe deterioration in auditory brainstem response threshold. Middle ear examination revealed extensive changes in the Ultrastop-treated group and medium changes in the gentamicin-treated group. Ultrastop applied topically to the guinea pig middle ear caused significant middle ear inflammation and hearing impairment.