Abstract

During the past 10 years, clinicians have used two-piece implants as a one-piece system for immediate loading to accomplish early recovery for function and esthetics. The statistical analysis by the Institute of Clinical Materials demonstrates high survival rates of 92.3 +/- 8.3%. Animal experiments of beagle dogs have been carried out to analyze successful conditions of immediate loading according to the dependency of bone formation--resorption upon the biomechanical stress--strain of bone. Histometric investigations clarified that the micromotion of less than 30 microns at the implant-bone interface did not interfere with the osteogenesis and new bone growth at the implant-bone interface. Bone formation and resorption are discussed from the standpoint of minimum effective strain on living bone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.