Abstract
This paper focuses on failure detection in the electrical flight control system of Airbus aircraft. Fault tolerance is designed into the system by the use of stringent processes and rules, which are summarized below. Monitoring of the system components is part of this fault-tolerant design. This paper covers the particular case of oscillatory failure monitoring in the electrical flight control system. The main characteristics and consequences of these failures are presented. The detection of oscillatory failures on the A380 is considered, together with the concept of analytical redundancy to detect these failures. A nonlinear actuator model is used to generate a residual on which the failure is detected by oscillation counting. Real application and benefits of the overall method are also presented. The results are highly satisfactory and the overall method is currently implemented on A380 flight control computers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.