Abstract

Separating oscillating flows in an internal, adverse pressure gradient geometry are studied experimentally. Simultaneous velocity and pressure measurements demonstrate that the minor losses associated with oscillating flow in an adverse pressure gradient geometry can be smaller or larger than those for steady flow. Separation is found to begin high in the diffuser and propagate downward. The flow is able to remain attached further into the diffuser with larger Reynolds numbers, small displacement amplitudes, and smaller diffuser angles. The extent of separation grows with L 0/h. The minor losses grow with increasing displacement amplitude in the measured range 10 < L 0/h < 40. Losses decrease with increasing Re δ in the measured range of 380 < Re δ < 740. It is found that the losses increase with increasing diffuser angle over the measured range of 12° < θ < 30°. The nondimensional acoustic power dissipation increases with Reynolds number in the measured range and decreases with displacement amplitude.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.