Abstract
Strain gages to measure only the stress intensity factor are only one or two kinds so far. They are not easy nor practical to analyze the stress intensity factor. Therefore, this paper reports on the development of strain gages dedicated to analyze the stress intensity factor easily and practically. The authors have made the strain gages for trial purpose. The strain gage was pasted to the crack tip of the plate tension specimens, having the opening mode crack. The authors carried out the tensile tests of the test pieces that pasted such strain gauges. As results, the experimental values of the opening mode stress intensity factors to be able to count by calculator were obtained within ±10% compared with analytical values.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of the Materials and Mechanics Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.