Abstract

ABSTRACT This study was designed to investigate the stress pattern and magnitude in periodontal ligament of maxillary central incisor for tipping and bodily tooth movement using finite element method and to determine the optimal orthodontic force required for bodily tooth movements compared to previous clinical, histologic, and laboratory studies. The three-dimensional FEM consisting of 27000 isoparametric elements of maxillary central incisor was constructed based on the average anatomic morphology given by Wheeler. Principal stresses in PDL were determined for tipping and bodily tooth movement. On application of optimal forces for tipping and bodily tooth movement, stress value seen in PDL was less, however the distribution of stress pattern coincided with the previous studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.