Abstract

Far-field potentials (FFPs) from muscles other than the abductor digiti minimi (ADM) may interfere with motor unit number estimation (MUNE) from that muscle. We identified the origin of each surface motor unit potential (SMUP) during hypothenar MUNE using the multiple point stimulation method in 20 control subjects by recording from individual ulnar-innervated muscles with a common proximal reference (pref). ADM SMUPs comprised 39.0% of the accepted SMUPs, followed by those from the fourth dorsal interosseous muscle (14.0%), the fourth lumbrical muscle (9.2%), and the second and third palmar interosseous muscles (8.8% each). The percentage of ADM SMUPs varied from 18% to 73% of accepted SMUPs among individual subjects. Accepted non-ADM SMUPs were usually much smaller than ADM SMUPs, and many more non-ADM SMUPs were excluded due to their small size. A large contribution from non-ADM or non-hypothenar SMUPs obscures the meaning of the MUNE value.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.